E-KEY Fire Alarm cables are purpose-built and NEC (National Electric Code) approved for fire alarms, signal control circuits, and other fire protection applications. They are suitable for installation between floors and in non-plenum areas. With manufacturing facilities in both China and Vietnam, E-KEY ensures competitive bulk Lightning to USB Cable supply, maintaining high-quality standards and offering competitive pricing.
Details of E-KEY Fire Alarm Cable:
E-KEY Fire Alarm cables are meticulously crafted to meet NEC (National Electric Code) standards and approved for fire alarms, signal control circuits, and other fire protection applications. They are suitable for installation between floors and in non-plenum areas. With manufacturing facilities in both China and Vietnam, E-KEY ensures a competitive bulk supply of Lightning to USB Cables, maintaining high-quality standards and offering competitive pricing.
Product Specifications:
These (UL) Approved Riser / FPLR-rated cables are NEC 760 FPLR, 800CMR, and 725 CL2R rated.
Constructed from two solid bare 100% copper conductors color-coded Black and Red.
Shielded with aluminum mylar and features a solid 24 AWG tinned copper drain wire.
Rated for 300 volts 75C with a (UL) approved Red PVC jacket.
Diameter of .178” and weighs 29# per 1000 Feet, with footage markings on the jacket.
Shipped on a 12” diameter plywood spool for ease of handling.
Customization Options:
All E-KEY products are proudly manufactured in China and Vietnam. For specific project needs, E-KEY offers a variety of electronic and fire alarm cables, available in different conductor counts, lengths, and jacket colors, including options rated Riser or Plenum, in shielded or non-shielded configurations.
For applications requiring reliable performance and adherence to safety standards, E-KEY Fire Alarm cables provide trusted solutions tailored to meet diverse industry requirements.
Advantages of E-KEY Fire Alarm Cable:
E-KEY offers two types of fire alarm cables:
FPLP Cable: This cable features two solid bare 100% copper conductors, color-coded black and red, insulated with Low Smoke PVC. It comes with a choice of 5 different Low Smoke PVC Jacket colors for circuit identification.
FPLR Cable: Made of two solid bare 100% copper conductors, color-coded black and red, this cable has a UL-approved red PVC jacket. A rip cord is included for easy stripping.
Both the FPLR and FPLP cables are rated for 300 volts at 75°C. They come with footage markings on the jacket for easy tracking of remaining cable on the spool, which ships on a 12” diameter plywood spool.
Specifically, the E-KEY 500-foot red 16/2 fire alarm/security cable is housed in an easy-to-use pull box. It consists of 2 16 AWG wires inside a FPLR-rated outer jacket. This cable is primarily used for power-limited fire circuits and is also suitable for security systems, which are often interconnected.
Our FPLR security/fire alarm cables meet UL 1424 standards, suitable for vertical runs exceeding one floor, as specified in section 760-154(B) of the National Electrical Code ANSI/NFPA 70. Additionally, these cables meet UL 1666 standards for flame propagation height.
OEM/ODM Solutions for E-KEY Fire Alarm Cable:
Our OEM/ODM certified fire alarm cables are meticulously designed to enhance your business operations. We offer high-quality products that cater to diverse applications, providing flexibility and a competitive edge in the market. Our certified cables ensure high speed, high definition, and superior sound clarity across various settings. Additionally, our portable fire alarm cables are conveniently transportable to any location you require. Purchasing our fire alarm cables wholesale offers significant advantages for a wide range of applications.
Fire Alarm Cable Factories in China and Vietnam
E-KEY Electronics has been a trusted manufacturer and supplier of fire alarm cables in China and Vietnam for nearly 20 years. With extensive experience in cable manufacturing, we ensure high-quality production in both locations. In addition to CAT cables, we offer customizable designs in various colors, shapes, and sizes.
Our modern manufacturing services for fire alarm cables focus on reducing costs, ensuring high certification standards, accelerating time-to-market, and enhancing your competitive advantage. With over 1200 dedicated employees in China and Vietnam, we are committed to serving our global customers and providing them with strategic advantages in the market.
Through advanced R&D, rigorous quality control, and efficient automated production lines, we have established reliability and credibility in the industry. This allows us to secure greater market share and opportunities across Western Europe, North America, Australia, and Asia. We prioritize building long-term, stable partnerships with our global customers, maintaining strong relationships built on trust and mutual benefit.
Why Choose E-KEYCertified Fire Alarm Cable?
Flexible Manufacturing System and Dynamic Dispatching from China and Vietnam
E-KEY Electronics has emerged as a trusted manufacturer and supplier of Fire Alarm Cables, serving markets in both China and Vietnam. We operate dual production lines for Fire Alarm Cables across these locations, ensuring seamless bulk supply to meet high-volume demands. Whether you choose dispatch from China or Vietnam, rest assured that our Fire Alarm Cables adhere to rigorous standards and are certified, with identical specifications across both regions.
Reliable Validation and Product Verification
Our manufacturing processes for Fire Alarm Cables are meticulously streamlined and standardized to guarantee superior quality and certification. Equipped with state-of-the-art testing equipment from reputable brands like FLUKE, Chroma, YOKOGAWA, LECROY, TESEQ, and GwinSTEK, we uphold the highest industry standards. All materials used in our Fire Alarm Cables comply with RoHS, Reach, California 45 Act, and are Red Phosphorus free. Each Fire Alarm Cable undergoes comprehensive verification processes, including UL & CUL, FCC, DOE, CE, and NRCan certifications, before meticulous packaging and dispatch.
Packaging Design from Concept to Commercialization
Our adept team of designers specializes in Fire Alarm Cable packaging, providing end-to-end solutions tailored to diverse business needs. From product design to labeling and final packaging, we ensure that your Fire Alarm Cables stand out with impeccable visual appeal and functional design.
Warehousing, Logistics, and Inventory Solutions
We excel in inventory management and logistics, utilizing advanced order systems to maintain ample stock of Fire Alarm Cables. This enables prompt delivery to meet urgent customer needs, ensuring a seamless experience from order placement to receipt.
Comprehensive After-Sales Support
Our commitment extends beyond the sale with dedicated after-sales services aimed at assisting customers at every stage of their Fire Alarm Cable usage journey.
Customizable Fire Alarm Cable Solutions
We offer extensive customization options for Fire Alarm Cables, including color, shape, size, labeling, and packaging, ensuring that each product meets unique specifications or branding requirements. Our flexibility allows us to accommodate bespoke orders tailored to your exact needs.
Enhance Your Brand with Innovative Designs
Elevate your brand presence with our innovative Fire Alarm Cable designs, combining fashion-forward aesthetics with practical functionality. Customized labeling services further enhance brand visibility, leaving a lasting impression on your target market.
Certified Labeling Services
Upon production completion, choose from a variety of label designs and packaging options to personalize your Fire Alarm Cables and reinforce brand identity. Our customizable labeling services cater to specific branding preferences, ensuring your Fire Alarm Cables align with your brand strategy.
Free Samples for Quality Assurance
Experience our commitment to excellence firsthand with complimentary samples of our high-quality Fire Alarm Cables. Evaluate the superior quality and performance of our products risk-free before making a purchasing decision.
Contact us today to discover how E-KEY Electronics can fulfill your Fire Alarm Cable needs with precision, quality, and unparalleled customer service.
Fire Alarm Cable FAQ
Is a fire alarm cable stranded or solid?
Fire Alarm Cable meets the following industry standards:Fire Alarm cable is composed of solid bare conductors. Our Fire Alarm cable is also twisted for maximum flexibility. A fire Alarm cable is also available in Riser or Plenum. The fire Alarm can also be shielded with aluminum foil and a stranded tinned copper drain wire.
What is the difference between Class A and Class B wiring in a fire alarm?
In fire alarm systems, the real difference between Class B and Class A is that if the pathway is interrupted, Class B only sends a “Failure Signal” to the panel, and Class A provides an extra path to get around the interruption.
What are the different types of fire alarm circuits?
According to NEC Articles 760 and 725, there are two types of fire alarm system circuits: power restricted and non-power-limited. Power Limited Fire Alarm Wires typically work at 24 volts DC, whereas non-power-limited cables run at 120 volts AC.
What is the difference between Type 1 and Type 2 alarm cables?
Type 1 – Cable with a resistance of fewer than 100 Ohms/km and low smoke zero halogen insulating and sheathing. Type 2 – Cable with a resistance of fewer than 100 Ohms/km and PVC insulation and sheathing.
Does the fire alarm cable have to be in conduit?
Conduit or not to Conduit? NFPA and NEC 90 articles state that when installing a fire alarm system, any fire alarm wiring below 7 feet or in non-accessible areas must be installed in a metallic raceway, including behind drywall walls or hard ceiling surfaces.
Does the fire alarm cable need to be shielded?
If fire alarm cabling does not have other wires or cabling nearby or other sources of electrical interference, you may not need shielding. But in facilities near heavy electrical or mechanical equipment, the interference from these devices might mean you should use shielding to protect the fire alarm cable.
Can the fire alarm cable be run in a cable tray?
Power-limited fire alarm circuit cables and conductors shall not be placed in any cable, cable tray, compartment, enclosure, manhole, outlet box, device box, raceway, or similar fitting with conductors of electric light, power, Class 1, non—power-limited fire alarm circuits, and medium-power network-powered broadband …